動態(tài)信號分析儀 維修 租賃 銷售
生產(chǎn)廠家: 惠普/安捷倫
HP3562A動態(tài)信號分析儀是一種雙通道系統(tǒng)、頻譜、波形分析儀。有時域和頻域兩方面的分析能力,它具有100KHz的頻寬,150dB的測量范圍和80dB的動態(tài)分析范圍,因此,在機械、機電一體化控制系統(tǒng)中有著強大的分析解決問題的能力。是一款具有內(nèi)置信號源的通用FFT分析儀,適用于常見的頻譜和網(wǎng)絡(luò)分析,以及倍頻程、階次與關(guān)聯(lián)分析。內(nèi)置信號源具有可選的分析特性,可以優(yōu)化分析儀的性能,以便對噪聲、振動和聲學(xué)問題進行分析和故障診斷,評測并解決旋轉(zhuǎn)機械問題,以及表征控制系統(tǒng)參數(shù)。
詳細參數(shù)(PDF文檔)一
詳細參數(shù)(PDF文檔)二
1. 頻率
測量范圍:64μHz~100KHz
精度:頻率讀數(shù)誤差±0.004%
分辨率:跨距/800
跨距:
基本頻帶:跨距數(shù)66,最小跨距10.24mHz,最大跨距100KHz。
圖象電子放大:跨距數(shù)64,最小跨距20.48mHz,最大跨距100KHz。
時間記錄:800/跨距
2. 相位精度
10KHz以下為±2.50
10KHz至100KHz之間為±12.00
3. 動態(tài)范圍:所有畸變的和≤低于輸入范圍最大刻度值的80dB
4. 輸入阻抗:1MΩ±5%
The HP3562A Dynamic Signal Analyzer is a dual-channel fast Fourier
transform-based network, spectrum and waveform analyzer which provides analysis
capabilities in both the time and frequency domains. The dc-to-100 kHz
frequency range, 150 dB measurement range and 80 dB dynamic range of the
analyzer makes it a powerful solution for testing and analysis in electronics,
mechanics and electromechanical control systems.
Two high performance input channels and a built-in signal source (noise and sine
signals) address network analysis on the bench or in a test system. Zoom
analysis with frequency resolution to 25.6 uHz plus a powerful AM, FM and
PM demodulation function makes the HP3562A a versatile spectrum analyzer.
For transient or waveform analysis, signals can be sampled, digitized then
stored in an internal memory, or directed via HP-IB to an external disc drive
(without a computer). The stored waveforms can be recalled and analyzed in
the time and frequency domains (baseband and zoom analysis).
Additional features include a full range of data analysis capabilities such as
vector averaging, block-operation Waveform Math, a 40-pole/40-zero Curve Fitter
and Frequency Response Synthesis. Front panel operations can be automated
without a computer with built-in Auto Sequence programming, or with computers
through complete HP-IB programmability. For documentation of results with
hardcopy or mass storage, the HP3562A can control digital plotters and external
disc drives directly via HP-IB.
Accurate, high resolution frequency response measurements of electronic and mechanical systems can be performed with Linear Resolution FFT, Logarithmic Resolution and Swept Sine Analysis. A built-in signal source provides a variety of random noise and sinewave signals to meet the requirements of the system under test.
Linear Resolution is the measurement technique common to all Dynamic Signal Analyzers. In the HP3562A, 2048-point time records are Fourier-transformed in to 801-line frequency spectra. For network analysis, frequency response magnitude and phase, as well as input and output power spectra, can be measured with 801 lines of resolution. Accuracy for the frequency response magnitude and phase is ± 0.1 dB and ± 0.5°.
Logarithmic Resolution uses the speed of Linear Resolution FFT measurements to create frequency responses similar to a log-sweep swept sine test. Linear Resolution points are combined internally (rather than just reformatted), on the fly, to create 80-point-per-decade measurements over 1 to 5 decades. Start and stop frequencies can be selected in a 1-2-5 sequence from 0.1 Hz to 100 kHz (for a 0.1 Hz start frequency the maximum stop frequency is 10 kHz - 5 decades).
The Swept Sine mode reconfigures the HP3562A as a powerful swept sine frequency response analyzer. The source can generate linear or logarithmic sweeps with increasing or decreasing frequency; user-selectable sweep rate and resolution are also standard source functions. Input channel functions include user-selectable averaging and integration time; automatic input ranging can be activated to provided over 130 dB of dynamic range for measurements of high performance systems.
On-line analysis of distortion, drift, modulation and phase noise can benefit from the speed and accuracy of the HP3562A. High resolution measurements are typically 100 times faster than tuned spectrum analyzers - and, since the HP3562A is an FFT-based analyzer, you can see transient events that a tuned analyzer would probably miss.
The HP3562A is essentially a dual-channel spectrum analyzer which provides resolution to 25.6 µHz anywhere within the dc-to-100 kHz measurement range. Single channel accuracy is ± 0.15 dB with 80 dB of dynamic range. Modulation analysis can be performed on either or both channels with harmonic and sideband markers as well as with the built-in demodulation capability: zoom measurements can be AM, FM, or PM demodulated with carrier frequencies up to 99.9 kHz.
Waveform and Transient Analysis
Perform complete analysis of waveforms and transients in the time and frequency domains. Sampled and digitized waveforms can be stored in internal memory (signal-channel Time Capture) or on disc in an external disc drive (single- or dual-channel Time Throughput). Data can be recalled for time domain analysis as single time records or as a compressed display of up to 10 time records (Time Capture mode). Data can also be recalled for baseband and zoom analysis in the frequency domain, with vector averaging if needed.
A complete array of triggering capabilities are included to enhance both waveform recording modes. Pre- and post-trigger delays can be specified to capture the rising edge of a transient or to compensate for delays in the system under test.
Data Throughput to a Disc Drive
When access to prototypes is limited, make your test time more efficient with the Time Throughput capability: through direct control of external disc drives, the HP3562A can store time data directly to disc without a computer. Set up a measurement and specify the quantity of single- or dual-channel data to be collected. Time data will be sampled, digitized and stored on disc for later analysis as individual time records or as baseband and zoom frequency spectra.
Hardcopy and Mass Storage with Plotters and Disc Drives
To speed and simplify documentation of results, direct control of plotters and disc drives via HP-IB is a standard feature in the HP3562A. Literally anything displayed on the analyzer screen can be plotted or saved on disc: measurement results, setup state tables, synthesis tables, curve fit tables and Auto Sequence or Auto Math program listings. Plotting is enhanced with user-selectable line types, pens and paging controls. For mass storage operations, files can be given 8-letter user-defined names; and disc catalog can be recalled and displayed to show file name, type (data, setup, etc.) and date and time of storage.
Automation for Improved Productivity
Versatile automation capabilities and a wide range of response-only or stimulus/response measurement functions in the HP3562A help you create productive solutions for your automated testing needs. As a standalone solution, the analyzer can "learn" a series of keystrokes and then perform them on command (Auto Sequence programming). Up to five Auto Sequence programs can be stored internally, with additional programs stored in an external disc drive.
For networked HP-IB systems, the HP3562A provides complete HP-IB programmability. Custom display graphics and messages can be created through direct programming of the high resolution vector display - user-defined soft key menus can also be created to simplify interactive testing. Rear-panel outputs for large screen displays are also standard.
Dual-Channel, Dynamic Signal Analyzer 64 µHz to 100 kHz
Frequency Response Measurements
Spectrum Analysis
Waveform and Transient Analysis
Hardcopy and Mass Storage
Specifications
Frequency
Spans | Baseband | Zoom |
# of spans | 66 | 64 |
min span | 10.24 mHz | 20.48 mHz |
max span | 100 kHz | 100 kHz |
time record (sec) | 800/span | 800/span |
Amplitude
Input
Trigger
Source
咨詢電話: 132- 4173- 5460 , 郵箱: 52634729@QQ.com